Tamarac

Tamarac Building Safety Inspection

Tamarac's building safety inspections follow the standard Broward County applies county-wide, run through the City's own building department. Two reports are required — a structural safety inspection report and an electrical safety inspection report — each prepared on the County's approved forms.

Condominium associations account for much of Tamarac's covered inventory, alongside the neighbourhood retail plazas and commercial buildings along its main corridors. Vilano Engineering delivers both reports and submits them together as one sealed package.

If You've Received a Notice

The notice tells you which reports are due and the date they are due by. What it leaves out is what the inspections involve and what the building department will be looking for.

Send us the notice and we will tell you what the work covers.

Send us your notice →

What the Reports Cover

The structural report covers load-bearing elements and the condition of the structure. The electrical report covers the service and distribution equipment, including the equipment serving parking areas, walkways and exterior lighting.

The County's Forms

The reports go on Broward County's approved structural and electrical forms; a firm's own format is not accepted. Every page carries the seal of the professional responsible for that scope, and the package is filed with the City's building department.

What the Standard Reaches

The scope runs past the walls of the building. Elevated walkways, decks and parking structures attached to a covered building are inspected as part of it, as are docks and seawalls where a covered building has them. For a plaza or a garden-style condominium property that means the covered walkways and the parking areas come in with the building.

What to Have Ready

  • The certificate of occupancy, which establishes the building's age
  • The notice received from the City
  • Prior recertification reports
  • Structural and electrical drawings
  • Access to electrical rooms, and a point of contact for scheduling

Tamarac and the Surrounding Jurisdictions

The requirement is the same one that applies in Coconut Creek to the east and Margate to the north-east. No thermographic scan is required anywhere in Broward, unlike Miami-Dade.

For what happens between receiving a notice and closing the file, see what to do when you receive a recertification notice.

Frequently Asked Questions

What kinds of building does the programme cover in Tamarac?

Condominium buildings, retail plazas and commercial and office property are all covered. The City's building department confirms whether a given building falls within it.

Do I need separate firms for the structural and the electrical report?

No. Vilano Engineering delivers both and submits them as a single sealed package.

Is a thermographic scan part of the inspection?

No. Broward's standard does not include an infrared thermography requirement.

Are the covered walkways and parking areas inspected too?

Yes. Elevated walkways, decks and parking structures attached to a covered building are within the scope.

What if deficiencies are found?

They need to be permitted, completed and inspected, with a re-inspection affidavit. Getting the permits is the building owner's responsibility, and the engineer cannot certify a building on work that was never permitted.

Vilano Engineering, LLC is a licensed engineering firm providing building recertification and safety inspections, infrared thermography, electrical design, expert witness services, developer turnover, and property condition assessments.

Nicholas Strachan, PE

Licensed Professional Engineer — Arizona, California, Florida, Georgia, Idaho, New York, North Carolina, Texas

Certified Level II Thermographer

Licensed Plans Examiner — Florida

25+ years in engineering design, inspection, and quality assurance

Request a proposal →